Marine Generator Sets:

Cat C2.2 Marine Generator Set

C2.2 (Single Phase)
Minimum Rating
16 ekW (16kVA)
Maximum Rating
27 ekW (27 kVA)
Frequency
50 Hz or 60 Hz
Speed
1500 rpm (50Hz) or 1800 rpm (60 Hz

Cat® C2.2 Diesel Marine Generator Set has single phase ratings of 50 Hertz at 16.0 and 22.5 ekW and 60 Hertz at 19.0 and 27.0 ekW that meet U.S. EPA Tier 3 and EU IW emission standards.The Cat® C2.2 also has three phase ratings of 50 Hertz at 16.0 and 22.5 ekW and 60 Hertz at 19.5 and 27.0 ekW that meet U.S. EPA Tier 3 and EU IW emissions standards. This marine gen set is available in 12 or 24 volt as an open gen set or as an enclosed package.



Product Specs

  • Generator Set Specifications

  • Minimum Rating
    16 ekW (16kVA)
    Maximum Rating
    27 ekW (27 kVA)
    Frequency
    50 Hz or 60 Hz
    Speed
    1500 rpm (50Hz) or 1800 rpm (60 Hz
    Minimum Rating
    16 ekW (16kVA)
    Maximum Rating
    27 ekW (27 kVA)
    Frequency
    50 Hz or 60 Hz
    Speed
    1500 rpm (50Hz) or 1800 rpm (60 Hz
    Emissions/Fuel Strategy
    EPA Tier 3, IMO NST, EU IW
  • Generator Set Configurations

  • Emissions/Fuel Strategy
    EPA Tier 3, IMO NST, EU IW
  • Engine Specifications

  • Engine Model
    C2.2, In-line 4, 4-Stroke-Cycle Diesel
    Aspiration
    Naturally Aspirated
    Bore
    3.31in
    Stroke
    3.94in
    Displacement
    135.0in3
    Governor Type
    Electrical Ischronous
    Engine Model
    C2.2, In-line 4, 4-Stroke-Cycle Diesel
    Aspiration
    Naturally Aspirated
    Bore
    3.31in
    Stroke
    3.94in
    Displacement
    135in³
    Governor Type
    Electrical Ischronous
    Fuel System
    Fuel filter — RH or LH service, fuel priming, fuel transfer pump, flexible fuel lines
  • Generator Specifications

  • Frame Size
    2.2
    Excitation
    AREP
    Pitch
    2/3 pitch
    Number of Poles
    4
    Number of Leads
    4
    Insulation
    Class H
    IP Rating
    23
    Wave Form Deviation - Line to Line
    <2%
    Voltage Regulator
    Steady State
    Voltage Regulation
    ±0.5%
  • Dimensions & Weights

  • Length - Open Set
    45in
    Length - Enclosed Set
    46in
    Width - Open Set
    20.5in
    Width - Enclosed Set
    24in
    Height - Open Set
    32in
    Height - Enclosed Set
    31in
    Minimum Approximate Weight
    857lb
    Maximum Approximate Weight
    1027lb

Equipment

  • Air Inlet System
    • Air cleaner, single element canister type with rain cap (open generator set only)
  • Cooling System
    • Belt-driven centrifugal jacket water pump, gear-driven seawater pump, heat exchanger with copper nickel tubes, expansion tank
  • Control System
    • Electronic isochronous governor
  • Exhaust System
    • Watercooled exhaust manifold and elbow
  • Fuel System
    • Fuel filter — RH or LH service, fuel priming, fuel transfer pump, flexible fuel lines
  • Generator
    • Single-phase — brushless, shunt excited, 4-pole, 4-lead reconnectable with class H insulation, automatic voltage regulation ±0.5%, 2/3 pitch, IP23 water protection, solid state voltage regulator with integral voltage adjustment potentiometer, connection poles;
  • Lube System
    • Lubricating oil, oil filter (RH), dipstick (RH), fumes disposal (closed system)
  • Mounting System
    • Anti-vibration mounts, connected to drip tray and steel base sitting on PVC foam sound-absorbent pad
  • Protection System
    • Electronic automatic safety shutdown for low oil pressure, high water temperature, high exhaust (wet exhaust only) temperature, and overspeed
  • Starting System
    • 12 or 24 volt electronic starting motor, 12 volt 55 amp alternator
  • General
    • Single-side service (RH), decals, literature